Standard available functions:
|
VD
|
VI
|
VL
|
VU
|
VM
|
Distributes and amplifies (one input):
- 1:4 LTC (EBU/SMPTE)
- 1:4 Serial signals RS232/422/485
- 1:4 4 Seconds impulse telegram signals
|
.


|
.
|
.
|
.
|
.
|
Distributer, amplifier and demultiplexer
1:4, 2:4 LTC (EBU/SMPTE)
|
.
|
.
|
|
.
|
.
|
Distributer, amplifier and demultiplexer
1:4, 2:4 LTC to analog clock signals
|
.
|
.
|
.
|
|
.
|
Distributer and amplifier (one input)
1:6 10 MHz (continuous wave)
|
.
|
.
|
.
|
.
|
|
Distributer and amplifier (one input)
1:6 LTC (EBU/SMPTE) or IRIG-B
|
.
|
|
.
|
.
|
.
|
|
Redundant fail-proof output signals
|
.
|
|
.
|
.
|
|
RUBIDIUM Distribution modules:
The Alpermann+Velte Rubidium "V" series modules are signal distribution, demultiplexer and amplification modules for all outgoing signals available from our Rubidium generator modules. The following signals can be distributed with our RUB "V" series: LTC, IRIG-B, 10 MHz continuous wave, analog clock signals and RS 232/422/485 serial data strings (please view above chart for applicable module/signal).
This distributor and amplifier modules are designed to distribute incoming signals such as a "real time" over long distances and to various signal receivers. Selected modules also have an analog clock driver and can power and control up to 180 of our analog clocks, in up to four different world time zones.
The "VI" and "VM" series modules also have an error monitor function for signal failure(s), enabling a completely redundant outgoing signals. These signals can be monitored with our RUB IE module via SNMP or an internet browser. The VL and VU distribution modules are also demultiplexers for all the time signals available from our GT Time Code Generator. Each output is selectable from available time zones or A,B,C,D;E;F "MTD" times.
"V" series module features… at a glance:
Distributes and amplifies 1:4 RUB GT signals:
-one LTC input to four LTC (EBU/SMPTE) outputs
-one RUB GT input to four RS232/422/485 signals outputs
-one RUB GT input to four analog clock signals
Distributes and amplifies:
-one input to six LTC(EBU/SMPTE) or IRIG-B outputs
-output monitoring with a redundant change-over switcher
Distributes and amplifies:
-two LTC inputs to four LTC (EBU/SMPTE) outputs
-four different time zones possible
(demultiplexed from Alpermann+Velte's MTD A,B,C,D,E,F)
Distributes and amplifies:
- two LTC inputs to four analog clock signal outputs
-four different time zones possible
(demultiplexed from Alpermann+Velte's MTD A,B,C,D,E,F)
Distributes and amplifies:
-one 10MHz continuous wave input (e.g. from RUB GPS 10MHz) to six 10 MHz continuous wave outputs
-output monitoring with programmable redundant change-over switcher
Example of a distribution and rear connection panel:

Specifications:
|
RUBIDIUM V series modules
|
VD
|
VI
|
VL
|
VU
|
VM
|
|
Specification
|
|
Operating voltage
|
8 - 30 VDC
|
|
Dimensions rear panel
|
RUB1 "1RU" version 103x44mm / 4,06x1,73 inches / RUB3 "3RU" version - 8HP, 3RU
|
|
Dimensions circuit board
|
(WxL): 100x160mm / 3.94x6,30 inches
|
|
Weight
|
0.2 kg approx.
|
|
Connections
|
|
Input
|
1 x DSUB9M
|
1 x RJ45
|
2 x RJ45
|
2 x RJ45
|
1 x BNC
|
|
Output
|
1 x DSUB9F
|
1 x DSUB9F
|
4 x RJ45
|
4 x RJ45
|
6 x BNC
|
|
LTC input signals
|
|
Signal
|
Balanced signals
|
|
Input impedance
|
18 kOhm
|
|
Input signal level
|
100 mV - 5V
|
|
LTC distribution amplifier output
|
|
Signal
|
Balanced signals
|
Balanced signals
|
Balanced signals
|
|
|
|
Output gain
|
1 +- 1%
|
1 +- 1%
|
Adjustable 100 mVp-p - 4,9 Vp-p
|
|
|
Other signals
|
|
RS485
|
Input/output balanced signals
|
|
|
RS485
|
.
|
7 failure signals
|
4 configurable I/O`s
|
4 configurable I/O`s
|
7 failure signals
|
|
Extra functions
|
|
Configurable / programmable
|
no
|
yes
|
yes
|
yes
|
yes
|
|
SNMP compatible
|
no
|
yes
|
yes
|
yes
|
yes
|
|
Flash memory for easy online updates
|
no
|
yes
|
yes
|
yes
|
yes
|
|
Hot swapping compatible
|
yes
|
yes
|
yes
|
yes
|
yes
|
Ordering information: RUB "V" series
Module "V" must be used in conjunction with a housing and a power supply.
|
Product ordering ID:
|
Module name
|
Functional description
|
|
RUB1 VD
|
Distribution unit for H1 housing
|
LTC, RS232/422/485 and analog clock signal distributor and amplifier
|
|
RUB1 VI
|
Distribution unit for H1 housing
|
LTC, IRIG B signal distributor and amplifier (redundant signals)
|
|
RUB1 VL
|
Distribution unit for H1 housing
|
LTC (SMPTE/EBU) signal distributor and amplifier (four time zones max.)
|
|
RUB1 VU
|
Distribution unit for H1 housing
|
Analog clock signal distributor and amplifier (four time zones max.)
|
|
RUB1 VM
|
Distribution unit for H1 housing
|
10 MHz signal distributor and amplifier (redundant signals)
|
We reserve the right to modify specifications without notice.
|