RUBIDIUM VM Module:
Features
|
LTCdecoder for MTD
Four built-in amplifiers
Distribution amplifier for serial telegrams
Four RS232 and RS422 interfaces
|
The VM module amplifies one 10 MHz sinus signal to six individual 10 MHz outputs. In case of a faulty signal
output, a seventh amplifier can be switched to one of the six distributing ports.
RUBIDIUM H1 VM module rear view
LEDs located on the front of the module indicate the operating status. Built-in GPIs can be programmed to
signal errors or other warnings. The backlit keys on the front of the module can individually be configured with the included
software. The setup (configuration) of the module is made using a PC via the USB or Ethernet port (optionally).
Example of a 10 MHz distribution system, 12 outputs
Example of a redundant 10 MHz distribution system, 17 outputs
| In order to ensure a fail-safe operation, all signals are analyzed and monitored. In the event of an error,
the appropriate output is switched to the reserve amplifier. The changeover is programmable as follows:
|
|
Immediately (automatically)
At a specified time (automatically)
Manually (by pushing one of the programmable keys)
|
Available functions can be selected by configuration over the housing’s USB interface. If a RUB IE Ethernet
module is on hand, configuration can also be made via a standard web browser.
A status monitor can be accessed at any time. SNMP is available in combination with an IE modul.
RUBIDIUM H1 VM module front view
Specifications VM module
|
Input
|
|
Connector
|
|
BNC (IEC 169-8), 75 Ω
|
|
DC range
|
|
± 5 V
|
|
Input impedance
|
|
75Ω
|
|
Signal specifications
|
Frequency range: 10 MHz ± 5%
Amplitude range: 0.2 - 2.5 Vpp signal input at 75Ω
|
Output
|
|
Connector
|
|
BNC (IEC 169-8), 75 Ω
|
|
Output impedance
|
|
75Ω
|
|
Gain
|
|
1 ± 1%
|
|
GP_1 - GP_7
|
|
Output specification
|
Open collector output of a NPN Darlington transistor.
Max. power dissipation: 200 mW.
|
|
“High” state:
|
|
External pull-up needed to a positive power
source of less than or equal to 30 VDC, typically 1 kΩ when
connected to an external +5 VDC power source
|
|
“Low” state:
|
Output switched to GND.
Maximum collector current = 200 mA DC, not fused.
Collector-emitter saturation voltage: @100 mA: typ. 0.9 (≤ 1.1V)
|
Others
|
|
Operating voltage
|
|
12 - 30 VDC
|
|
Power consumption (without any load)
|
|
max. 1.5 W (GPI_1 - GPI_7 unconnected)
|
|
Weight
|
|
0.5 kg approx.
|
|
Dimensions Rub H1
|
2 circuit board (W x D): 100 x 160 mm / 3.94 x 6.30“
Rear panel: 103 x 44 mm / 4.06 x 1.73“
|
|
Dimensions Rub H3
|
|
Rear panel: 3RU, 8HP
|
|
Environmental characteristics, operating
|
Temperature: +5 °C - +40 °C
Relative humidity: 30 % - 85 %, non-condensing
|
|
Environmental characteristics, non-operating
|
Temperature: -10 °C - +60 °C
Relative humidity: 5 % - 95 %, non-condensing
|
Product ordering ID VM modules
|
|
RUB1 VM
|
|
Distribution module 1:6 10 MHz continuous wave with output monitoring and a redundant change-over switcher
|
|
RUB3 VM
|
|
Distribution module 1:6 10 MHz continuous wave with output monitoring and a redundant change-over switcher
|
|
The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see
our overview leaflet for more information.
|
We reserve the right to modify specifications without notice.
|