products Abstand Rubidium Series 1 & 3: Module VI Abstand Alpermann+Velte

Leaflets:

PDF-document VI - module


Manuals:

PDF-document VI - module



VI button
Abstand
RUB housing
H1-Module in a 19"/1 RU-Housing


RUBIDIUM VI Module:


Features
Four built-in amplifiers
1:4 Distribution of LTC, Serial and Telegram Signals
Two RS232 Outputs
Four RS422 Outputs
Compatible with Alpermann+Velte's MTD signal



The VI module amplifies one LTC or one IRIG-B signal to six equal outputs. In case of a faulty signal output, a seventh amplifier can be switched to one of the six distributing ports.

RUBIDIUM H1 VI module rear view
RUBIDIUM H1 VI module rear view

LEDs located on the front of the module indicate the operating status. Built-in GPIs can be preprogrammed to signal errors or other warnings. The backlit keys on the front of the module can be individually configured with the included software. The setup (configuration) of the module is made using a PC via the USB or Ethernet port (optionally).

Buttons


Connection Plan 1
Example of a LTC distribution system, 12 outputs


Connection Plan 2
Example of a redundant IRIG-B distribution system, 18 outputs

In order to ensure a fail-safe operation all signals are monitored. In the event of an error, the appropriate output is switched to the reserve amplifier. The changeover is programmable as follows:
  • Immediately (automatically)
  • At a specified time (automatically)
  • Manually (by pushing one of the programmable keys)


  • Circuit Diagram

    Available functions can be selected by configuration over the housing’s USB interface. If a RUB IE Ethernet module is on hand, configuration can also be made via a standard web browser.

    Configuration 1

    Configuration 2

    Monitoring

    A status monitor can be accessed at any time. SNMP is available in combination with an IE module.


    RUBIDIUM H1 VI module front view
    RUBIDIUM H1 VI module front view


    VI Draw rear
    VI Draw rear

    Specifications VI module

    LTC input
    Format
    According to ANSI/SMPTE 12M-1999, balanced signals
    Input impedance
    18 kΩ
    Signal level
    100 mVpp - 5 Vpp, auto-ranging
    Frequency
    19 - 33 frames/s

    IRIG input
    Format
    IRIG-B123 according to IRIG STANDARD 200-98 or according to
    AFNOR NF S 87-500, amplitude modulated carrier signal with
    1 kHz carrier frequency, balanced signals
    Input impedance
    18 Ω
    Signal level
    100 mVpp - 5 Vpp, mark amplitude, auto-ranging

    LTC or IRIG outputs
    Format
    According to signal input, balanced signals
    Output impedance
    < 50 Ω
    Gain
    1 ± 1%
    GP_1 - GP_7
    Output specification
    Open collector output of a NPN Darlington transistor.
    Max. power dissipation: 200 mW.
    “High” state:
    External pull-up needed to a positive power source of less than or equal to 30 VDC, typically 1 kΩ when connected to an external +5 VDC power source
    “Low” state:
    Output switched to GND. Maximum collector current = 200 mA DC, not fused. Collector-emitter saturation voltage: @100 mA: typ. 0.9 (≤ 1.1V)

    Others
    Operating voltage
    12 - 30 VDC
    Power consumption
    max. 1.6 W (GPI_1 - GPI_7 unconnected)
    Weight
    0.5 kg approx.
    Dimensions Rub H1
    2 circuit board (W x D): 100 x 160 mm / 3.94 x 6.30“
    Rear panel: 103 x 44 mm / 4.06 x 1.73“
    Dimensions Rub H3
    Rear panel: 3RU, 8HP
    Environmental characteristics, operating
    Temperature: +5 °C - +40 °C
    Relative humidity: 30 % - 85 %, non-condensing
    Environmental characteristics, non-operating
    Temperature: -10 °C - +60 °C
    Relative humidity: 5 % - 95 %, non-condensing

    Product ordering ID VI modules
    RUB1 VI
    Distribution module 1:6 LTC (EBU/SMPTE) or IRIG-B with output
    monitoring and a redundant change-over switcher
    RUB3 VI
    Distribution module 1:6 LTC (EBU/SMPTE) or IRIG-B with output
    monitoring and a redundant change-over switcher

    Legend:
    LTC:
    Linear Time Code (SMPTE 12M-1999)
    IRIG-B:
    Inter Range Instrumentation Group (according to IRIG STANDARD 200-98)

    The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

    We reserve the right to modify specifications without notice.