RUBIDIUM VD Module:
Features
|
Four built-in amplifiers
1:4 Distribution of LTC, Serial and Telegram Signals
Two RS232 Outputs
Four RS422 Outputs
Compatible with Alpermann+Velte's MTD signal
|
| The module VD is a versatile distributor and amplifier. Injected input signals, e.g. signals provided
by the MTD system, are available at its four outputs.
|
The VD module is able to distribute / amplify typical signals like:
|
LTC
RS485
SERIAL (RS232 + RS422, e.g. for reference time)
TELEGRAM (e.g. to access analog clocks)
|
LEDs located on the front of the module and a fault detector relay indicate the present operating status of
the module.
RUBIDIUM H1 VD module front view
RUBIDIUM H1 VD module rear view
| The VD’s main task is buffering and distributing the output signals of GT or GL generator modules.
|
User consoles like the TCU can be connected directly to the VD module.
|
In case of an exclusive processing of LTCor RS485 signals, it is possible to cascade multiple VD modules in
order to increase the amount of output sockets.
Analog clocks are accessible via the TELEGRAM protocol. Two-Wire-Mode as well as Four-Wire-Mode is supported.
Specifications VD module
|
LTC input
|
|
Connector
|
|
Balanced signals LTC_IN_A and LTC_IN_B
|
|
Input impedance
|
|
18 kΩ
|
|
Signal level
|
|
100 mVpp - 5 Vpp, auto-ranging
|
|
Frequency
|
|
0 - 100 kHz
|
LTC output
|
|
Connector
|
|
Balanced signals LTC_OUT_A and LTC_OUT_B
|
|
Output impedance
|
|
< 50 Ω
|
|
Gain
|
|
1 ± 1%
|
TELEGRAM OUT
|
|
Signal
|
|
Output stage of the TELEGRAM IN signal amplifier
Seconds impulse telegram. Nominal level = 12 V
(Version 1)/ = 23 V (Version 2) without load
|
|
Maximum current
|
|
Fused by a 200 mA auto-recovery fuse each output stage.
A continuous current of up to 120 mA can be applied over the
whole specified operating temperature range.
|
|
VCC12_Out
|
|
Signal
|
|
12 VDC voltage output
|
|
Maximum curent
|
|
Fused by a 500 mA auto-recovery fuse each output stage.
A continuous current of up to 330 mA can be applied over the
whole specified operating temperature range.
|
Others
|
|
Operating voltage
|
|
nominal value: 24 VDC
|
|
Power consumption (without any load)
|
hardware version 1: max. 1.6 W
hardware version 2: max. 2.1 W
|
|
Weight
|
|
0.2 kg approx.
|
|
Dimensions Rub H1
|
2 circuit board (W x D): 100 x 160 mm / 3.94 x 6.30“
Rear panel: 103 x 44 mm / 4.06 x 1.73“
|
|
Dimensions Rub H3
|
|
Rear panel: 3RU, 8HP
|
|
Environmental characteristics, operating
|
Temperature: +5 °C - +40 °C
Relative humidity: 30 % - 85 %, non-condensing
|
|
Environmental characteristics, non-operating
|
Temperature: -10 °C - +60 °C
Relative humidity: 5 % - 95 %, non-condensing
|
Product ordering ID VD modules
|
|
RUB1 VD
|
|
Distribution module 1:4 LTC, RS485, RS422, and analog clock signal outputs
|
|
RUB3 VD
|
|
Distribution module 1:4 LTC, RS485, RS422, and analog clock signal outputs
|
Legend:
|
|
LTC:
|
|
Linear Time Code (SMPTE 12M-1999)
|
|
The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see
our overview leaflet for more information.
|
We reserve the right to modify specifications without notice.
|