products Abstand Rubidium Series 1 & 3: AT Alpermann+Velte

Leaflets:

PDF-document AT - module


Manuals:

PDF-document AT - module



AT button
Abstand
RUB housing
H1 modules, 19" 1 RU housing



RUBIDIUM Series 1 & 3 AT module:


Features
Time Code Reader
Time Code Converter
Time Code Inserter
LTC, VITC, UMID, CVBS
MTD compatible
TC_link compatible
Programmable in/output GPIs
4 programmable front profile buttons
Optional available features
Video bypass relay (option B)
Sony 9P protocol converter (option S)
Programmable offset (option O)
Converter biphase/CTL to LTC(option P)

The Rubidium series module AT is a Time Code inserter and converter designed to work with analog CVBS. All Time Code and data formats are processed by a builtin reader and/or generator which is compliant to the EBU/ SMPTE standards for NTSC and PAL video.

Standard features of the RUBIDIUM AT: Abstand analog video channel (CVBS), monochrome window insertion, VITC Time Code, LTC Time Code



The rear panel includes the following connectors:
  • LTC reader and generator
  • RS485/422/232 interface, Time Code or inserter data
  • 4 GPIOs for status signals, etc.
  • Relay contact output, programmable for Time Code zero value, additional failure Signal(s), etc.



  • AT H1 Front
    RUBIDIUM H1 AT module front


    AT H1 Rear
    RUBIDIUM H1 AT module rear

    AT H3 Rear
    RUBIDIUM H3 AT module rear



    Four configurable function keys are located on the front panel, allowing fast selection of functions or loading preset profiles. Backlit keys and four signal LEDs indicate the status of the module. A blue identification button shows the module's model name.

    Buttons

    Modules can be inserted in any order into the slots of the housing. Each slot position has its own address within the communal housing identification system. This enables a specific identification of each module within a bigger system. Alias names can be given to the hard stamped numerical address via the supplied configuration software.

    Via our IE Ethernet module, browser configuration, status control and SNMP functions are available. Every module is connected to an internal hot swappable bus, which bilaterally connects all modules within a particular housing. The internal bus can be distributed over several housings by using the RLC port.The RLC-plug contains a voltage feed, a failure relay output and a TC_link interface. TC_link is a real time capable proprietary interface, which is based on a customized RS485 interface.

    On the rearside of every housing, a PC interface (USB/RS232) can be found. This serial connection is used for configuration, status control, and also software and firmware updates.


    Circuit Diagram

    All data and Time Code formats received via RS232/422, LTC/VITC and TC_link can be inserted and converted.

    Up to fifteen separate user configurable windows can be inserted. Each inserter window has its own character set, character / windows attributes and source data. This defines the size of the window, as well as the character size and type. The inserters specifications can be stored and recalled via the configuration program as a profile. These profiles can be selected via the front-sided backlit buttons or via the serial PC configuration port.

    Configuration
    Web Browser Configuration

    Insert 1
    Insert 2


    Up to eight character sets from the local characters memory are stored in the module and can be recalled simultaneously for insertion. All insertions are available with and without a mask. Brightness values are separately selectable. Character size can be selected between 16 to 72 lines.



    Store Profile Font Compiler

    RUB configuration program


    Font size

    Fonts


    TC_link enables data interchange between different modules. A generator module could e.g. be set (triggered) with an external VITC value, which could simultaneously be converted into an ATC by an HT module. The modules are equipped with the following reader/generator/converter

    Converter matrix

    All data in the SMPTE/EBU metadata dictionary can be inserted as Ancillary Data. Methods for the implementation of these values are included. Various options for specifically designed or custom broadcast encoded transfers, e.g. the "monochrome transfer for MPEG" for transporting ancillary data are available and are supported by an optionally obtainable software. The universal input/output interfaces of all RUB modules allow for various optional converter features.

    Some popular examples are a biphase converter (CTL to Time Code), Sony 9PConverter and "offset-generation". There are many customer specific applications possible, so please do not hesitate to ask us for suggested solutions.


    Monitoring



    AT H1 Draw rear


    AT H3 Draw rear

    AT specifications

    Video input, loop, output
    CVBS analougue video signal: PAL 625/50, NTSC 525/60
    Connector
    BNC (IEC 169-8), 75 Ω
    Signal level
    800 mV ± 10%
    DC offset
    0.0 V ± 0.5 V
    Digital Data
    8-bit, 10-bit
    VITC input/output
    According to SMPTE 266M-2002

    LTC input / output

    Format
    According to ANSI/SMPTE 12M-1-2008
    Connector input
    - balanced signals LTC_IN_A and LTC_IN_B
    -via 3-pin XLR female (according to IEC 268-1)
    -via 2 pins of the 9-pin DSUB female GPI/LTC IN
    Connector output
    - balanced signals LTC_OUT_A and LTC_OUT_B
    - via 3-pin XLR male, optionally available instead of LTC input
    XLR female above (according to IEC 268-1)
    - via 2 pins of 9-pin D-SUB female SERIAL/LTC OUT
    Frame rates
    24, 25, 30, 30 drop
    Input impedance
    18kΩ
    Output impedance
    < 50 Ω
    Input signal level
    100 mVpp - 5 Vpp
    Output signal level
    Adjustable 140 mVpp - 4.9 Vpp

    GPI input / output

    GPI_1 ...GPI_4 Input specification
    Input “Low”: -15.0 to +1.0 V
    Input “High”: + 3.0 to +15.0 V
    Frequency: 0 - 1 Mhz
    GPI_1 ...GPI_4 Output specification
    Open collector output of a NPN transistor at 4k7
    pull-up resistor (5 VDC). Max. power dissipation: 200 mW. “High” state: 4.3 V
    (no laod). “Low” state: output switched to GND.
    Max. collector current: 100 mA DC, fused by a 100 mA: typ. 200 mV (± 600 mV), @ 10 mA: typ. 90 mV (± 250 mV).
    Frequency: 0 - 150 kHz.
    GPI_5 SPST-NO relay
    Contact resistance: 0.2 Ω
    Max. switching power: 10 W
    Max. switching voltage: 175 VDC
    Max. switching current: 0.5 A
    Max. transportable current: 0.8 A

    Standard features of the Time Code generator / reader

    Frame rate
    Selectable: 24, 25, 30, 30 drop, automatic
    Start value for the time addresses/binary groups
    Selectable
    Start value for the binary groups
    Selectable
    LTC output level
    Adjustable
    VITC lines
    Selectable
    Jam-Sync application
    Jam-Sync mode enabled / disabled
    Time offset selectable
    Jam-Sync only time, only user or both
    With stop or flying wheel feature

    Others

    4 frontside buttons
    Only RUB 1 modules
    Operating voltage
    8 - 30 VDC
    Power consumption
    max. 4.5W
    Weight
    0.4 kg approx.
    Dimensions Rub 1 (W x H x D)
    2 circuit board (W x D): 100x 160 mm / 3.94x 6.30 inch
    Rear panel: 103(B)x 44mm / 4.06x 1.37 inch
    Dimensions Rub 3
    19” 3 RU, 8HP
    Environmental characteristics, operating
    Temperature: +5°C - +40°C
    Relative humidity: 30% - 85%, non-condensing
    Environmental characteristics, non-operating
    Temperature: +10°C - +60°C
    Relative humidity: 5% - 95%, non-condensing

    Standard features of the video channel
    and character inserter

    Video channel
    VITC lines insert enabled/ disabled
    Charakter insert enabled/ disabled
    Character inserter
    Video window / position / format selectable

    Product ordering ID AT modules

    RUB 1 AT
    SDI digital video inserter and data processor module (1RU)
    RUB 3 AT
    SDI digital video inserter and data processor module (3RU)



    Option B
    Video bypass relay
    Option S
    Sony 9P protocol converter
    Option O
    Programmable offset
    Option P
    Converter biphase/CTL to LTC
    Option B
    Legend:
    LTC:
    Longitudinal Time Code
    (audio signal, SMPTE 12M-1-2008)
    VITC:
    Vertical Interval Time Code
    TC_LINK:
    Internal Communication of values between
    modules via the front bus


    The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

    We reserve the right to modify specifications without notice.