RUBIDIUM Series 1 & 3 AT module:
The Rubidium series module AT is a Time Code inserter and converter designed to work with analog CVBS. All Time Code and data formats are processed by a builtin reader and/or generator which is compliant to the EBU/ SMPTE standards for NTSC and PAL video.
RUBIDIUM H1 AT module front
RUBIDIUM H1 AT module rear
RUBIDIUM H3 AT module rear Four configurable function keys are located on the front panel, allowing fast selection of functions or loading preset profiles. Backlit keys and four signal LEDs indicate the status of the module. A blue identification button shows the module's model name.
Modules can be inserted in any order into the slots of the housing. Each slot position has its own address within the communal housing identification system. This enables a specific identification of each module within a bigger system. Alias names can be given to the hard stamped numerical address via the supplied configuration software. Via our IE Ethernet module, browser configuration, status control and SNMP functions are available. Every module is connected to an internal hot swappable bus, which bilaterally connects all modules within a particular housing. The internal bus can be distributed over several housings by using the RLC port.The RLC-plug contains a voltage feed, a failure relay output and a TC_link interface. TC_link is a real time capable proprietary interface, which is based on a customized RS485 interface. On the rearside of every housing, a PC interface (USB/RS232) can be found. This serial connection is used for configuration, status control, and also software and firmware updates.
All data and Time Code formats received via RS232/422, LTC/VITC and TC_link can be inserted and converted. Up to fifteen separate user configurable windows can be inserted. Each inserter window has its own character set, character / windows attributes and source data. This defines the size of the window, as well as the character size and type. The inserters specifications can be stored and recalled via the configuration program as a profile. These profiles can be selected via the front-sided backlit buttons or via the serial PC configuration port.
Web Browser Configuration
Up to eight character sets from the local characters memory are stored in the module and can be recalled simultaneously for insertion. All insertions are available with and without a mask. Brightness values are separately selectable. Character size can be selected between 16 to 72 lines.
TC_link enables data interchange between different modules. A generator module could e.g. be set (triggered) with an external VITC value, which could simultaneously be converted into an ATC by an HT module. The modules are equipped with the following reader/generator/converter
All data in the SMPTE/EBU metadata dictionary can be inserted as Ancillary Data. Methods for the implementation of these values are included. Various options for specifically designed or custom broadcast encoded transfers, e.g. the "monochrome transfer for MPEG" for transporting ancillary data are available and are supported by an optionally obtainable software. The universal input/output interfaces of all RUB modules allow for various optional converter features. Some popular examples are a biphase converter (CTL to Time Code), Sony 9PConverter and "offset-generation". There are many customer specific applications possible, so please do not hesitate to ask us for suggested solutions.
AT specifications
LTC input / output
GPI input / output
Standard features of the Time Code generator / reader
Others
Standard features of the video channel
Product ordering ID AT modules
We reserve the right to modify specifications without notice. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
© Alpermann+Velte 1996 - 2011; January 18, 2011 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||