Abstand
Deutsch
Home
About us
Sitemap
Products
Service
Projects
FAQ
Sales
Imprint
Email










Products AI / DI / XI modules Alpermann+Velte

Leaflets:

PDF-document AI, DI, XI
      - modules



Manuals:

PDF-document AI, DI, XI
      - modules


PDF-document Font compiler


Options:

PDF-document WSS decoder



AI button DI button XI button
Abstand
RUB housing
H1-Module im 19"/1 HE-Gehäuse


RUBIDIUM Series 1 & 3 AI / DI / XI modules:


Features
Video data platform for special applications
Video channel for analogue video (AI), SD digital video (DI)
   or HD digital video (HI)
Serial interfaces RS232, RS422 and RS485
4 programmable front profile buttons (RUB1 version)
Applications for
Daytime inserter (Option D)
GPS interface (Option G)
Internal clock module (Option T)
4 configurable GPIs (Option I)
Clip length inserter (Option C)
VPS decoder (Option V)
WSS decoder (Option W)

The hardware of these modules includes the serial interfaces RS232, RS422 and RS485, 4 x GPIO, one relay contact and a video channel corresponding to the type of the module:

RUBIDIUM AI: Abstand Analogue video channel (CVBS). Character inserter (monochrome) with adjustable brightness, transparency and background mask.
RUBIDIUM DI: Abstand SD digital video channel. Character inserter with selectable background mask. Color of character and mask separately adjustable.
RUBIDIUM XI: Abstand 3G/HD/SD digital video channel. Character inserter with selectable background mask. Color of character and mask separately adjustable.


Different character fonts and character sizes are selectable. Inside of the screen’s limitations, the inserted window can be positioned at will.

At least one option has to be selected for each module. A combination of options is only possible if specified.


The following options are available:

Option D
Daytime Inserter

Available for AI/DI/XI

An external reference (GPS, MSF) delivers a pulse per second (PPS), as well as time and date information via serial interface. The module decodes these data, calculates the local time, and visibly inserts a precise time (HH:MM:SS:1/100) into a video signal. Different formats of time and date representation are selectable. The external reference isn’t included.


Option G
External reference input

Addition to option D

This option includes an adapter cable, enabling an easy connection of the reference source.


Option T
Battery-buffered real-time chip

Addition to option D

With this option a battery-buffered realtime chip is added. This chip enables time and date functionalities after power-on, even if no external reference has been connected. Time and date can be set manually. If an external reference is connected, the real-time chip will automatically be synchronized to the reference.



Option C
Clip Length Inserter

Available for AI/DI/XI

This option has been developed to let the module operate with an automation system. While the automation system runs a playlist, a simple command can be transmitted to transfer the clip length to the module. The module starts a DOWN counter, converts this time into an LTC, and visibly inserts the time. Two independent DOWN counters are available. Different communication protocols can be selected.


Option V
VPS Decoder

Available for AI/DI

VPS: Video Program System. A module with this option decodes the data of line 16 according to the European Standard EN 300 294. The decoded data can visibly be displayed on a screen. GPIO signal outputs are signalling the state of selected bits. This option may be combined with option W.


Option W
WSS Decoder

Available for AI/DI

WSS: Wide Screen Signalling. A module with this option decodes the data of line 23 according to the European Standard EN 300 294. The decoded data can visibly be displayed on a screen. GPIO signal outputs are signalling the state of selected bits. This option may be combined with option V.


Option I
GGPIO special functions

Available forAI/DI/XI

With this option the GPIO inputs and outputs can process custom functionalities. This option may be combined with all other options.



Four configurable function keys are located on the front panel, enabling a fast selection of functions or loading of preset profiles. Backlit keys and four signal LEDs indicate the status of the module. A blue identification button shows the model name (AI, DI, XI).


DI Ausschnit
RUBIDIUM H1 DI module in H1 housing

Up to fifteen separate user configurable insertion windows can be positioned at will. Each inserted window has its own character set, character / windows attributes and source data. This defines e.g. the size of the inserted window, the character size and type, as well as the character and mask color. The inserter’s specifications can be stored and recalled via the configuration program as a profile. These profiles can be selected via the front-sided backlit buttons or via the serial PC configuration port.

Rubidium Config

Rubidium Color

Screen 1
Screen 2

Up to eight character sets from the local characters memory are stored in the RUB module and can be recalled simultaneously for insertion. DI and XI modules have full multi-color insertions, whereas the AI module’s insertions are restricted to black and white, or shades of grey. All insertions are available with and without a mask. Brightness and color values are separately selectable (where applicable). Character size can be selected between 16 to 72lines (AI/DI), or 16 to 139 (XI) lines.

Configuration

Profile

Compile

Screen 3

Screen 4


Functions common to all modules:

“Hot Swapping”, i.e. it is possible to insert or remove a module without interrupting the operation of other modules inside of the same frame.

RS232 and TC_link interfaces for accesing the internal bus of the chassis.

Flash memory containing the firmware, so configuration and updates are possible via a PC connection.

The PC program “RUBIDIUM CONFIGURATION”, and the RUBIDIUM SERIES HTTP server (via IE module) offer to access the module’s setup menus.

AI/DI/XI Front
RUBIDIUM H1 AI/DI/XI modules front view

AI/DI/XI Rear
RUBIDIUM H1 AI/DI/XI modules rear view

AI/DI/XI H1 Draw rear


AI/DI/XI H3 Draw rear

AI specifications

Power consumption
max. 5.0 W

VIDEO IN
Format
CVBS analog video signal: PAL 625/50, NTSC 525/60
Connector
BNC (IEC 169-8), 75 Ω
Signal level
1V ± 15 mV

VIDEO OUT
Format
Same as video input
Connector
BNC (IEC 169-8), 75 Ω
Gain
1 ± 1% (adjustable ± 4%)



DI specifications

Power consumption
max. 5.9 W

VIDEO IN
Format
Serial digital video, according to ANSI/SMPTE 259M
Connector
BNC (IEC 169-8), 75 Ω
Signal level
800mV ± 10 %

VIDEO OUT
Format
Same as video input
Connector
BNC (IEC 169-8), 75 Ω
Signal level
800mV ± 10 %
DC offset
0.0V ± 0.5 V



XI specifications

Power consumption
max. 6.2 W

VIDEO IN
Format
Serial digital video, according to ANSI/SMPTE 424M (3G),
ANSI/SMPTE 292M (HD) or ANSI/SMPTE 259M (SD)
Connector
BNC (IEC 169-8), 75 Ω
Signal level
800mV ± 10 %

VIDEO OUT
Format
Same as video input
Connector
BNC (IEC 169-8), 75 Ω
Signal level
800mV ± 10 %
DC offset
0.0V ± 0.5 V


AI/DI/XI common specifications

GPIO - input specification
Input “Low”: -2.0 to +1.0 V
Input “High”: +3.0 to +24.0V
Impedance: 4.7 Ω
Frequency: 0 - 1 MHz
GPIO - output specification
Open collector output of a NPN transistor at 4k7 pull-up
resistor (5 VDC). Max. power dissipation: 200 mW.

“High” state: 4.3 V (no load).

“Low” state: output switched to GND
Max. collector current: 100 mA DC, fused by a 100 mA auto-
recovery fuse.
Collector-emitter saturation voltage: @100 mA: typ. 200 mV
( 600 mV), @10 mA: typ. 90 mV ( 250 mV)

Frequency: 0 - 150 kHz
SPST-NO Relay
Contact resistance: 0.2 Ω
Max. switching power: 10 W
Max. switching voltage: 175 VDC
Max. switching current: 0.5 A
Max. transportable current: 0.8 A
Mechanical and Environmental



Mechanical and Enviromental

Weight
0.4 kg approx.
Dimensions RUB 1 AI/DI/XI (W x H x D)
2 circuit boards (W x D): 100 x 160 mm/3.94 x 6.30 inch
Rear panel: Rub H1: 103 (B) x 44 mm/4.06 x 1.73 inch
Rub H3: 8HP, 3RU
Environmental characteristics, operating
Temperature: +5 °C to +40 °C
Relative humidity: 30 % to 85 %, non-condensing
Environmental characteristics, non-operating
Temperature: -10 °C to +60 °C
Relative humidity: 5 % to 95 %, non-condensing
Operating voltage
12 - 30 VDC



Product ordering ID AI, DI, HI modules

RUB 1 AI
CVBS video data platform (1RU)
RUB 3 AI
CVBS video data platform (3RU)
RUB 1 DI
SDI digital video data platform (1RU)
RUB 3 DI
SDI digital video data platform (3RU)
RUB 1 XI
3G/HD/SDI digital video data platform (1RU)
RUB 3 XI
3G/HD/SDI digital video data platform (3RU)


Option Description Available for Combination possible with
D Inserter for date/time AI/DI/XI T G I
T Internal clock module AI/DI/XI D
G GPS interface AI/DI/XI D
W WSS decoder AI/DI V I
V VPS decoder AI/DI W I
I 4x GPIO spec. functions AI/DI/XI D W V CLIP
C Clip length inserter AI/DI/XI I



The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

We reserved the right to modify specifications without notice.

Erde
Abstand

Deutsch | Home | About us | Sitemap | Products | Service | Projects | FAQ | Sales | Imprint | Contact us



© Alpermann+Velte 1996 - 2011; December 09, 2011