RUBIDIUM Series 1 & 3 AI / DI / HI module:
The Rubidium series modules „AI, DI and HI“ are Time inserters and converters designed for use with three different video formats. All time and data formats are processed by a built-in reader and/or generator which are compliant to the EBU/SMPTE standards for NTSC and PAL video. All three modules have almost identical features and differ mainly in the type of video that they can process:
|
RUBIDIUM AI:
|
|
analogue video channel (CVBS),monochrome window insertion. Time, Date and Data, VPS, WSS
|
|
RUBIDIUM DI:
|
|
digital video channel (SDI), digital video channel window insertion Time, Date and Data, VPS, WSS
|
|
RUBIDIUM HI:
|
|
(HD-SDI and SDI), window insertion, Time, Date and Data
|
|
There are connectors on the rear side of the module for:
|
|
LTC reader and generator
|
|
RS485/422/232 interface, Time, Dateor inserter data, Ancillary
Data
|
|
4 GPI inputs, 2 GPI outputs, CTL or PPS inputs, status signals, etc.
|
|
Relay contact output, programmable for Time Code zero value, additional failure Signal(s), etc.
|
RUBIDIUM H1 AI / DI / HI module front
|
RUBIDIUM H1 AI / DI / HI module rear
|
Four configurable function keys are loca-ted on the front panel, allowing fast selection of functions or loading of preset profiles. Backlit keys and four signal LED's indicate the real time status of the module. A blue identification button shows the modules model name (AI, DI, HI)
|
RUBIDIUM H1 DI module in H1 housing
|
Modules can be inserted in any order into the slots of the housing. Each slot position has its own address within the communal address of the systems housing identifi-cation address. This enables each module to be specifically identified within a bigger system. To simplify the location and iden-tification of a module, alias names can be given to the hard stamped numerical address via the supplied configuration software.

Configuration and status report are also available with Microsoft Windows:
Via our (IE) Ethernet module browser,module configuration, status control and SNMP functions are possible. When any RUB module is inserted into any of our housings, each module is automatically connected to an internal “hot swappable” bus. This internal bus bilaterally connects all modules within that particular housing and can also be connected to other housings & modules via a RLC-plug loca-ted on the rear of all our housing models.The RLC-plug contains a voltage feed, a failure relay output and a TC_link interface. TC_link is a real time capable proprietary interface, which is based on a RS485 interface and an Alpermann+Velte user specific protocol. All data exchange between modules occurs via this RLC link. On the rear of every system housing is a PC interface (RS232). This serial conne-tion is used for configuration of the module, status control and also enables software and firmware updates.
Insertion and conversion of all data and Time Code formats received via (RS232/ 422, LTC/VITC/ATC/Ancillary Data and TC_link) interfaces is possible
Up to fifteen separate user configurable insertion windows is standard.Each inserter window has its own character set, character / windows attributes and source data. This defines e.g. the size of the insertion window, the character size and type as well as the character and mask colour. The inserters specifications can be stored and recalled via the configuration program as a profile. These profiles can be selected via the front-sided backlit buttons or via the serial PC configuration port.
Up to eight character sets from the local characters memory are stored in the RUB module and can be recalled simultaneously for insertion. The (DI/HI) have full multi-colour insertions whereas the (AI) modules insertions are restricted to black and white or shades of grey. All insertion are avai-lable with and without a mask. Brightness and colour values are separately selectable (where applicable). Character size can be selected between 16 to 72lines (AI/ DI) or 16 to 139 (HI) lines. Transparent masks and flashing characters are also standard.
Data interchange between modules is pos-sible via TC_link. For example this would allow a generator module to be set (trig-gered) with reader data of another mo-dule, e.g. a VITC value of an AT module to an ATC value to be generated on a HT module. The modules are equipped with the following reader / generator / conver-ter functions:
All data in the SMPTE/EBU metadata dictionary can be inserted as Ancillary Data. Methods for the implementation of these values are included. Various options for specifically designed or custom broad-cast encoded transfers, for e.g. the “monochrome transfer for MPEG” for transporting ancillary data are available and are supported by a optionally obtai-nable software. The universal input/output interfaces of all RUB modules allow for various optional converter features. Some popular examples are WSS, VPS, GPS receiver, Sony 9P-Converter and „offset-generation“ There are many customer specific applications possible, so please do not hesitate to ask us for suggested solution to a request you may have for your customer specific application
Features
Data Inserter
CVBS (AI), SDI (DI or HI), HD-SDI (HI)
4 programmable front profile buttons
|
Optional available features AI,DI,HI
Inserter for date/time (option D)
Internal battery buffered clock module (option T)
GPS interface (GPS receiver not included) (option G)
|
Optional available features AI,DI only
WSS data insertion (option W)- available with option V
VPS data insertion (option V)- available with option W
4 configurable GPI´s (option I)
|
AI / DI / HI specification
Video input, loop, output
Format AI
|
|
CVBS analougue video signal: PAL 625/50, NTSC 525/60
|
|
Format DI
|
|
Serial digital (SD) video, according to ANSI/SMPTE 259M
|
|
Format HI
|
|
Serial digital HD video, according to ANSI/SMPTE 259M or serial digital SD video; according to ANSI/SMPTE 259M
|
|
Connector (AI,DI,HI)
|
|
BNC (IEC 169-8), 75 Ohm
|
|
Signal level VIDEO IN (AI)
|
|
1V ± 15 mV
|
|
Signal level VIDEO IN (DI, HI)
|
|
800 mV ± 10%
|
|
Signal level LOOP OUT (AI
|
|
Loop-throught of VIDEO IN
|
|
Signal level LOOP OUT (DI, HI)
|
|
800 mV ± 10%
|
|
Signal level VIDEO OUT (AI)
|
|
Gain 1 ± 1%(adjustable ±4%)
|
|
Signal level VIDEO OUT (DI/HI)
|
|
800 mV ± 10%
|
Accuracy of the internal clock
|
PPS synchronous
|
|
Accuracy equal to the accuracy of the PPS signal
|
|
Temperature dependant drift (no PPS connector)
|
|
< ± 50 ppm (4 s/day)
|
|
Option T: acuracy of time during power-off state
|
|
< ± 7 ppm (0.6 s/day)
|
GPI
|
GPI_1 ...GPI_4 Input specification
|
Input “Low”: -15.0 to +1.0 V
Input “High”: + 3.0 to +15.0 V
Frequency: 0 - 1 Mhz
|
|
GPI_1 ...GPI_4 Output specification
|
Open collector output of a NPN transistor at 4k7
pull-up resistor (5V DC). Max. power dissipation: 200 mW. “High” state: 4.3 V
(no laod). “Low” state: output switched to GND.
Max. collector current: 100 mA DC, fused by a 100 mA autorecovery fuse
Collector-emitter saturation voltage:
@ 100mA: typ. 200mV (≤ 600mV)
@ 10mA: typ. 90mV (≤ 250mV)
Frequency: 0-150 kHz
|
|
GPI_5 SPST-NO relay
|
Contact resistance: 0.2 W
Max. switching power: 10 W
Max. switching voltage: 175 VDC
Max. switching current: 0.5 A
Max. transportable current: 0.8 A
|
24 VDC Out:
Output of the DC power supply of this modules,
normally = 24 VDC
|
Reversible fused.
A continous current of up to 120 mA can be applied over the whole specified operating temperature range. At an ambient temperature of e.g. 22° C the output switches to a high-resistance state after a few seconds if a current of 300 mA is applied.
|
Others
|
Operating voltage AI, DI, HI module
|
|
12 - 30 VDC
|
|
Power consumption AI module
|
|
max. 5.0W
|
|
Power consumption DI module
|
|
max. 4.5W
|
|
Power consumption HI module
|
|
max. 6.2W
|
|
Weight
|
|
0.4 kg approx.
|
|
Dimensions Rub 1 AI / DI / HI (WxHxD)
|
2 circuit board (WxD): 100x 160 mm / 3.94x 6.30 inch
Rear panel: 103(B)x 44mm / 4.06x 1.73 inch
|
|
Environmental characteristics, operating
|
Temperature: +5°C - +40°C
Relative humidity: 30% - 85%, non-condensing
|
|
Environmental characteristics, non-operating
|
Temperature: +10°C - +60°C
Relative humidity: 5% - 95%, non-condensing
|
Product ordering ID AI, DI, HI modules
|
RUB 1 AI
|
|
CVBS video inserter module (1 RU)
|
|
RUB 1 DI
|
|
SDI digital video data inserter module (1 RU)
|
|
RUB 1 HI
|
|
HD/SDI digital video data inserter module (1 RU)
|
|
Option B
|
|
Inserter for date/time
|
|
Option T
|
|
Internal clock module (battery buffered)- avalable with option D
|
|
Option G
|
|
GPS interface (GPS receiver not included)- avalable with option D
|
|
Option W
|
|
WSS data insertion - avalable with option V
|
|
Option V
|
|
VPS data inertion - avalable with option V
|
|
Option I
|
|
4 configurable GPI´s
|
The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.
We reserved the right to modify specifications without notice.
|
|