products Abstand Rubidium Series 1 & 3 Abstand Alpermann+Velte

Operating Manual:
pdf-file.... zip- file

Universal Video Data Processor "Rubidium Series 1" (RUB1):

rb1_front Abstand H1 module

Universal Video Data Processor "Rubidium Series 3" (RUB3):

rb3_front Abstand H3 module


The system modules are:

Master
Time Code
Generator
GT button
Master
Time Code
Generator
GL button
Reference
Switch
SR button
LTC
Switch
SL button
VITC
Switch
SV button
Ethernet
Interface
IE button
IRIG-B
Master
Generator
GI button
IRIG-B
Switch
SI button
Analog Video
Time Code
Inserter/
Converter
AT button
AV button
AI button
Digital Video
Time Code
Inserter/
Converter
DT button
DV button
DI button
HD Video
Time Code
Inserter/
Converter
HT button
HV button
HI button
Power Supply
RUB1
PS button
PQ button
Power Supply
RUB3 /
RUB S1/T1
PT button
PE button
GPS
Receiver
GPS10 button
GPS16 button
GPS17 button
LTC-
(MTD/TTT)
Demulti-
plexer
VL button
VU button
Distribution
Amplifier
VD button
VI button
VM button
Brochure:
pdf-file.... zip- file

Software Updates
Descriptions:

Housing concept:
H1
D1
H3
S1
T1

Compact System

Redundandent System

NTP server

SNMP agent

Font compiler


High technology in an improved format - because times have changed...

Combining our vast experience with the newest technology required a change. Our new Rubidium Series is a result of over 20 years of experience in the broadcast data field.

Rubidium stands for quality and high precision , which is what you can expect from this new series of products.



Module System:

  • Real-time front bus communication between modules (TC_link)

  • DVITC, LTC, VITC and VPS processing

  • ATC, UMID and Metadata processing

  • Distribution and signal amplifiers

  • NTP server synchronisation and SNMP functions available with Ethernet module

rb_front
RUB3 module
User friendly menu operations:

  • Programmable keys for complex functions (RUB H1 only)

  • Flexible windows software configuration

  • Optional internet browser configuration (Mac compatible)

rb_menu

rb_browser

New 19" Module Chassis:

  • 1RU 19" carriers for one to four RUB modules

  • 3RU 19" carriers up to 21 RUB ultra compact modules

  • Redundent power supplies available

  • Simple interconnection of RUB frames

rb_front rb_front
RUB1 chassis and modules

Service:

  • Easy access serial connection for software updates and special configuration needs

  • Optional Ethernet module for external communication of status and data

  • Status and failure reports available with SNMP

rb3_persp
RUB3 chassis and modules



To start, all you need is a Rubidium housing and power supply. Then insert the required "RUB" module and your ready to go. All RUBIDIUM modules boast an easy set-up procedure by using a windows compatible configuration software, which automatically identifies the module and allows for a simple set-up via a RS232 serial port or via an internet browser software (function of "IE" module).

sys diagram

rb_insert Communication of all available values between modules in one or more connected "RUB" housings is accomplished though our intelligent front bus system (TC_link).

The inserter can handle up to fifteen independend windows. Each with its own attributes like color, size and function. Other standard features include genlocked Time Code generation and a configurable GPI interface.

rb_keypad For your convenience we also have four programmable functions keys, hot swapping capability and a flash memory chip to enable easy firmware updates. A user selectable serial interface (RS232, RS422 or RS485) can be optionally configured depending on your required protocol.




rub1_front rub1_back rub3_front rub3_back

The capabilities of all RUB modules at a glance:

Rubidium System: Master Time Code Modules
Functions available: GT GI GL GPS 16 GPS 17 GPS 10MHZ SL SV SI SR IE
Generates Master LTC yes . yes . . . . . . . . . . . . .
Generates VITC yes . . . . . . . . . . . . . . .
Generates IRIG-B . yes . . . . . . . . . . . . . .
Switches two incoming LTC's . . . . . . . yes . . . . . . . .
Switches two incoming VITC's . . . . . . . . yes . . . . . . .
Switches two incomming IRIG-B signals . . . . . . . . . yes . . . . . .
Switches two incoming GPS signals . . . . . . . . . . yes . . . . .
Switches two incoming 10MHz signals . . . . . . . . . . yes . . . . .
GPS receiver with two 10MHz outputs . . . . . yes . . . . . . . . . .
GPS receiver with pps/Time/Date outputs . . . yes yes yes . . . . . . . . . .
IRIG B compatible yes yes . . . . . . . . . . . . . .
LTC(MTD)generator compatible yes . yes . . . . . . . . . . . . .
TC_link output of status data yes yes yes . . yes . yes yes yes yes . . . . .
Error detection (monitoring functions) yes yes yes . . yes . yes yes yes yes . . . . .
GPI failure outputs (programmable) yes yes yes . . yes . yes yes yes yes . . . . .
SNMP compatible (with RUB IE module) yes yes yes . . yes . yes yes yes yes . . . . .
LED's with status information yes yes yes . . yes . yes yes yes yes . . . . .
Four illuminated programmable keys yes yes yes . . yes . yes yes yes yes . . . . .
Windows configuration and setup yes yes yes . . yes . yes yes yes yes . . . . .
Updateable firmware (flash memory) yes yes yes . . yes . yes yes yes yes . . . . .
Ethernet 10 baseT communication . . . . . . . . . . . . yes . . .

Rubidium System: Inserter / Converter Modules
Functions available: AT AV AI DT DV DI HT HV HI DA DY
Generates LTC yes . . . yes . . . yes . . . . . . .
Generates VITC yes yes . . . . . . . . . . . . . .
Generates DVITC . . . . yes yes . . yes yes . . . . . .
Generates ATC . . . . yes yes . . yes yes . . yes yes . .
Generates Ancillary Data . . . . yes yes . . yes yes . . yes yes . .
Reads LTC yes . . . yes . . . yes . . . . . . .
Reads VITC yes yes . . . . . . . . . . . . . .
Reads DVITC . . . . yes yes . . yes yes . . . . . .
Reads ATC . . . . yes yes . . yes yes . . yes yes . .
Reads Ancillary Data . . . . yes yes . . yes yes . . yes yes . .
Reads Data via TC_link or serial interface yes yes yes . yes yes yes . yes yes yes . yes yes . .
Convert inputs and TC_link to LTC yes . . . yes . . . yes . . . . . . .
Convert inputs and TC_link to VITC yes yes . . . . . . . . . . . . . .
Convert inputs and TC_link to DVITC . . . . yes yes . . yes yes . . . . . .
Convert inputs and TC_link to ATC . . . . yes yes . . yes yes . . yes yes . .
Convert inputs and TC_link to Ancillary Data . . . . yes yes . . yes yes . . yes yes . .
Insert (burn in) inputs or outputs as well as TC_link into FBAS yes yes yes . . . . . . . . . . . . .
Insert (burn in) inputs or outputs as well as TC_link into SDI . . . . yes yes yes . yes yes yes . yes yes . .
Insert (burn in) inputs or outputs as well as TC_link into HD-SDI . . . . . . . . yes yes yes . . . . .
LTC(MTD) compatible yes . . . yes . . . yes . . . . . . .
TC_link output of status data yes yes yes . yes yes yes . yes yes yes . yes yes . .
Error detection (monitoring functions) yes yes yes . yes yes yes . yes yes yes . yes yes . .
GPI failure outputs (programmable) yes yes yes . yes yes yes . yes yes yes . yes yes . .
SNMP compatible (with RUB IE module) yes yes yes . yes yes yes . yes yes yes . yes yes . .
LED's with status information yes . yes . yes . yes . yes . yes . yes . . .
Four illuminated programmable keys yes . yes . yes . yes . yes . yes . yes . . .
Windows configuration and setup yes yes yes . yes yes yes . yes yes yes . yes yes . .
Updateable firmware (flash memory) yes yes yes . yes yes yes . yes yes yes . yes yes . .

Rubidium System: Distribution / Demultiplexer Modules and
Power Supplies
Functions available: VD VI VL VU VM PS PQ PT PE
Distributes and amplifies (one input):
1:4 LTC (EBU/SMPTE)
1:4 Serial signals RS232/422/485
1:4 Seconds impulse telegram signals
yes . . . . . . . . . . . . . . .
LTC or IRIG-B distributer and amplifier (one input), 1:6 . yes . . . . . . . . . . . . . .
LTC distributer, amplifier and demultiplexer 1:4, 2:4 . . yes . . . . . . . . . . . . .
LTC to analog clock signals distributer, amplifier and demultiplexer 1:4, 2:4 . . yes yes . . . . . . . . . . . .
10 MHz (continuous wave) distributer and amplifier (one input) 1:6 . . . . yes . . . . . . . . . . .
Redundant fail-proof output signals . yes . . yes . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
60 Watts power . . . . . . . . . yes yes yes . . . .
20 Watts power . . . . . . . . . . . . yes . . .
Overload protection . . . . . . . . . yes yes yes yes . . .
Failure relay . . . . . . . . . yes yes yes . . . .
Staus monitor and SNMP features . . . . . . . . . yes yes yes . . . .
OLED Display and LTC reader . . . . . . . . . . yes . . . . .

Legend:
LTC: Longitudinal Time Code (audio signal, SMPTE 12M-1999)
VITC: Vertical Interval Time Code (FBAS analog video, SMPTE RP 159-1995)
DVITC: Vertical Interval Time Code (SDI digital video, SMPTE 266 M)
ATC: Ancilliary Time Code (SMPTE 291M-1998)
TC_link: Internal communication of values between modules via the front bus
LTC(MTD) compatible: Compatible to Alpermann+Velte's Time Timer Time Code system

We reserve the right to modify specifications without notice.