products Abstand Rubidium Series 1 & 3: Module VM Abstand Alpermann+Velte

Leaflets:

PDF-document VM - module


Manuals:

PDF-document VM - module



VM button
Abstand
RUB housing
H1-Module in a 19"/1 RU-Housing


RUBIDIUM VM Module:


Features
LTCdecoder for MTD
Four built-in amplifiers
Distribution amplifier for serial telegrams
Four RS232 and RS422 interfaces



The VM module amplifies one 10 MHz sinus signal to six individual 10 MHz outputs. In case of a faulty signal output, a seventh amplifier can be switched to one of the six distributing ports.

RUBIDIUM H1 VM module rear view
RUBIDIUM H1 VM module rear view


LEDs located on the front of the module indicate the operating status. Built-in GPIs can be programmed to signal errors or other warnings. The backlit keys on the front of the module can individually be configured with the included software. The setup (configuration) of the module is made using a PC via the USB or Ethernet port (optionally).

Buttons


Connection Plan 1 Example of a 10 MHz distribution system, 12 outputs


Connection Plan 2 Example of a redundant 10 MHz distribution system, 17 outputs


In order to ensure a fail-safe operation, all signals are analyzed and monitored. In the event of an error, the appropriate output is switched to the reserve amplifier. The changeover is programmable as follows:
  • Immediately (automatically)
  • At a specified time (automatically)
  • Manually (by pushing one of the programmable keys)


  • Circuit Diagram

    Available functions can be selected by configuration over the housing’s USB interface. If a RUB IE Ethernet module is on hand, configuration can also be made via a standard web browser.

    Configuration 1

    Configuration 2

    A status monitor can be accessed at any time. SNMP is available in combination with an IE modul.


    Monitoring

    VM Front
    RUBIDIUM H1 VM module front view


    VM Draw rear
    VM Draw rear

    Specifications VM module

    Input
    Connector
    BNC (IEC 169-8), 75 Ω
    DC range
    ± 5 V
    Input impedance
    75Ω
    Signal specifications
    Frequency range: 10 MHz ± 5%
    Amplitude range: 0.2 - 2.5 Vpp signal input at 75Ω

    Output
    Connector
    BNC (IEC 169-8), 75 Ω
    Output impedance
    75Ω
    Gain
    1 ± 1%
    GP_1 - GP_7
    Output specification
    Open collector output of a NPN Darlington transistor.
    Max. power dissipation: 200 mW.
    “High” state:
    External pull-up needed to a positive power source of less than or equal to 30 VDC, typically 1 kΩ when connected to an external +5 VDC power source
    “Low” state:
    Output switched to GND.
    Maximum collector current = 200 mA DC, not fused.
    Collector-emitter saturation voltage: @100 mA: typ. 0.9 (≤ 1.1V)

    Others
    Operating voltage
    12 - 30 VDC
    Power consumption (without any load)
    max. 1.5 W (GPI_1 - GPI_7 unconnected)
    Weight
    0.5 kg approx.
    Dimensions Rub H1
    2 circuit board (W x D): 100 x 160 mm / 3.94 x 6.30“
    Rear panel: 103 x 44 mm / 4.06 x 1.73“
    Dimensions Rub H3
    Rear panel: 3RU, 8HP
    Environmental characteristics, operating
    Temperature: +5 °C - +40 °C
    Relative humidity: 30 % - 85 %, non-condensing
    Environmental characteristics, non-operating
    Temperature: -10 °C - +60 °C
    Relative humidity: 5 % - 95 %, non-condensing

    Product ordering ID VM modules
    RUB1 VM
    Distribution module 1:6 10 MHz continuous wave with output monitoring and a redundant change-over switcher
    RUB3 VM
    Distribution module 1:6 10 MHz continuous wave with output monitoring and a redundant change-over switcher

    The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

    We reserve the right to modify specifications without notice.