Products AV module Alpermann+Velte

Leaflets:

PDF-document AV - module


Manuals:

PDF-document AV - module

PDF-document Font compiler



AV button
Abstand
AV button
H1 modules, 19" 1 RU housing



RUBIDIUM Series 1 & 3 AV module:


Features
Time Code Reader
Time Code Converter
Time Code Inserter
VITC
CVBS
MTD compatible
TC_link compatible
Optional available features
Video bypass relay (option B)
IRIG-B reader

The Rubidium series module AV is a Time Code inserter and converter designed to work with analog CVBS video. All Time Code and data formats are processed by a built-in reader and/or generator which is compliant to the EBU/SMPTE standards for NTSC and PAL video.

RUBIDIUM AV: Abstand analog video channel (CVBS), monochrome window insertion, VITC-Time Code

A blue tag on the coverage shows the identification of the module.

AV Ausschnit
RUBIDIUM H1 AV module in H1 housing


AV Front
RUBIDIUM H1 AV module front view



AV Rear
RRUBIDIUM H1 AV module rear view


AV H3 rear
RUBIDIUM H3 AV module rear view


Modules can be inserted in any order into the slots of the housing. Each slot position has its own address within the communal housing identification system. This enables a specific identification of each module within a bigger system. Alias names can be given to the hard stamped numerical address via the supplied configuration software.

Via our IE Ethernet module, browser configuration, status control and SNMP functions are available. Every module is connected to an internal hot swappable bus, which bilaterally connects all modules within a particular housing. The internal bus can be distributed over several housings by using the RLC port.

The RLC-plug contains a voltage feed, a failure relay output and a TC_link interface. TC_link is a real time capable proprietary interface, which is based on a customized RS485 interface. On the rear side of every housing, a PC interface USB or RS232 can be found.

This serial connection is used for configuration, status control, and also software and firmware updates.

AV Schaltbild

Up to fifteen separate user configurable windows can be inserted. Each inserter window has its own character set, character/windows attributes and sourcedata. This defines the size of the window, as well as the character size and type. The inserters specifications can be stored and recalled via the configuration program as a profile. Profiles can be selected via the front-sided backlit buttons or via the serial PC configuration port.

Rubidium Config
Web Browser Configuration


Rubidium Color

Screen 1
Screen 2


Up to eight character sets from the local characters memory are stored in the module and can be recalled simultaneously for insertion. All insertions are available with and without a mask. Brightness values are separately selectable. Character size can be selected between 16 to 72 lines.

profil

compile

Configuration Program


Screen 3
Screen 4

TC_link enables data interchange between different modules. A generator module could e.g. be set (triggered) with an external VITC value, which could simultaneously be converted into an ATC by an XV module. The modules are equipped with the following reader/generator/converter functions:


converter matrix

All data in the SMPTE/EBU metadata dictionary can be inserted as Ancillary Data. Methods for the implementation of these values are included. Various options for specifically designed or custom broadcast encoded transfers, e.g. the “monochrome transfer for MPEG” for transporting ancillary data are available and are supported by an optionally obtainable software.

There are many customer specific applications possible, so please do not hesitate to ask us for suggested solutions.


Monitoring



DT Draw rear


DT Draw H3 rear

AV specifications

Video input, loop, output
Format
CVBS analougue video signal: PAL 625/50, NTSC 525/60
Connector
BNC (IEC 169-8), 75 Ω
Signal level
800 mV ± 10%
DC offset
0.0V ± 0.5V
Digital Data
8-bit, 10-bit
LTC input
According to ANSI/SMPTE 12M-1999
IRIG-B input
According to IRIG STANDARD 200-98
VITC input / output
According to ANSI/SMPTE 12M-1999

Standard features of the Time Code generator / reader

Frame rate
Selectable: 24, 25, 30, 30 drop, automatic
Start value for the time addresses/binary groups
Selectable
Start value for the binary groups
Selectable
VITC lines
Selectable
Jam-Sync application
Jam-Sync mode enabled/disabled

Others

Operating voltage
12 - 30 VDC
Power consumption AV module
max. 2.8W
Weight
0.2 kg approx.
Dimensions Rub 1 (W x H x D)
Circuit board (W x D): 100x 160 mm / 3.94x 6.30 inch
Rear panel: 103(B)x 44mm / 4.06x 1.37 inch
Dimensions Rub 3
19” 3 RU, 4HP
Environmental characteristics, operating
Temperature: +5°C - +40°C
Relative humidity: 30% - 85%, non-condensing
Environmental characteristics, non-operating
Temperature: +10°C - +60°C
Relative humidity: 5% - 95%, non-condensing

Standard features of the video channel
and character inserter

Video channel
VITC lines insert enabled/disabled
Character insert enabled/disabled
Character inserter
Video window/position/format selectable

Product ordering ID AV modules

RUB 1 AV
CVBS video inserter and data processor module (1 RU)
RUB 3 AV
CVBS video inserter and data processor module (3 RU)


Option B
Video bypass relay


The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

We reserve the right to modify specifications without notice.

Legend:

VITC:
Vertical Interval Time Code
(FBAS analogue video SMPTE RP 159-1995)
TC_LINK:
Internal Communication of values between modules via the front bus

Erde
Abstand

Deutsch | Home | About us | Sitemap | Products | Service | Projects | FAQ | Sales | Imprint | Contact us



© Alpermann+Velte 1996 - 2011; December 09, 2011