Timer Control Unit
TCU/TCUE
for Alpermann+Velte’s
MTD (Multiple Time Display) system

TCU Module




Features
Large seven segment LED digit numerical time display(s)
Additional three line OLED alpha/numerical display
Backlit keypad
Programmable function keys
RS485 connection to A+V´sGT Time Code generator
USB configuration and setup
Ethernet connection to A+V’s MTDoE system
Ethernet configuration and setup
Assignable user rights management
Built-in Time Code reader and MTD demultiplexer
Four programmable GPIs (two inputs & two outputs)


Working together with various TV broadcasters and studios, Alpermann+Velte developed the Multiple Time Display system (MTD). With its flexible design, the multi-timer and display system can easily be used in many different types of applications. Even multiple studios can be interconnected and share all generated information.

A MTD system consists of a central generator, digital displays and/or analog clocks coupled with a timer control unit. The central generator generates a specially encoded LTC signal we call LTC(MTD). In this LTC(MTD) there are six different times (or timers) available, such as real-time, different time zones, dates and various up or down-counting timers.

The LTC(MTD) includes all six times in it’s userbits. Distributed to a digital display, one of the six available times or timers can be selected to be visualized. The Timer Control Unit enables an easy submission of time and timers as well as a status indication.

TCU 1HE
“TCU H1”, 19” / 1RU, with second display



TCU Front

TCU is a user console with a numerical LED display, an OLED information display and a backlit keypad:

  • The LED display has 15 mm digit height, 7- segment LEDs in red. It displays a time in the format(HH:MM:SS).
  • The color of the OLED display (Organic Light Emitting Diode) is yellow. It displays the status information.
  • The keypad has 18 backlit keys,15 keys have an inscription.
  • All keys except the numeric keys 0-9 can be programmed. The three keys without inscriptions are special function keys, where the currently selected function is indicated directly on the OLED display.
  • Optional 2nd Display (TCU H1).
  • LTC input for display functions or reference time
  • Voltage supply via an external power supply or directly from the Rubidium VL or VD module.
  • The TCU can either be used in a tabletop format or mounted in a 19“-rack with 3RU/21HP. The TCU H1 housings dimensions are 19“ 1RU.

TCUE is a control unit for MTDoE systems (MTD timer distribution over ethernet; for further information please see our seperate brochure). The TCUE’s main functions differ in the following points:

  • Ethernet port for a mobile operation
  • Voltage supply via an external power supply or PoE (Power over Ethernet)
  • Tabletop housing only
MTD Table



Internal comparators and other available functions can be used for control of the built-in audio beeper, various GPIs and for changing the display formats. The expiration of a stopwatch could entail a buzzing signal, a signal at one of the GPI outputs, and also include a flashing reminder indication. Timer start and stop signals can also be received from external sources to any of the two input or output GPIs.

Several studios belonging to a larger complex can use multiple TCUs connected to only one central generator. By enabling certain access rights to individual TCUs, it can be guaranteed that the individual studio only has access to change its allocated times or timers.

Schaubild

Software updates and configuration can be done over the USB or Ethernet port (TCUE only). Tools and the latest firmware versions can be downloaded at www.alpermann-velte.com

Config

TCU specifications

LTC/MTD IN (RJ45 and DSUB9F):
RS485
Balanced inputs or outputs of the RS485 serial interface
LTC IN
Format
ANSI/SMPTE 12M-1999, balanced
Signal level
60 mVpp - 5 Vpp, auto-ranging
Input impedance
47 Ω
Ethernet (TCUE)
standard ethernet port, MTDoE
Configuration Port
USB
Universal serial bus “B” jack
Compatibility
USB 1.1 (compatible with USB 2.0)
Flash software upgradable
Yes
2x GPI input (via RJ45)
Programmable
Zero-crossing, external trigger, etc...
2x GPI input (via RJ45)
Fader contact, start, stop, reset, hold, etc...


Others

Operating voltage
10-30 V DC
Power consumption
max. 5W, 3W typical
Weight TCU/TCUE, tabletop housing
0.6 kg approx.
Weight TCU 19”, table or rack mountable unit
0.2 kg approx.
Weight TCU H1, 19”/1RU housing
0.4 kg approx.
Dimensions TCU/TCUE, tabletop housing
W x H x D 112 x 5 1 x 162 mm/4.41 x 2.01 x 6.38 inches
Dimensions TCU 19”, rack mountable unit
W x H x D 106 x 129 x 40 mm/4.17 x 5.01 x 1.57 inches
Dimensions TCU H1, 19”/1RU housing
19” 1RU
Environmental characteristics, operating
Temperature: +5 °C - +40 °C
Relative humidity: 30 % - 85 %, non-condensing
Environmental characteristics, non-operating
Temperature: -10 °C - +60 °C
Relative humidity: 5 % - 95 %, non-condensing
Cable length
Up to 10 m

Product ordering ID

TCU
Time control unit, tabletop housing
TCUE
Timer control unit, Ethernet interface, tabletop housing
TCU 19
Time control unit, table or rack mountable
TCU H1
Time control unit, 19”/1RU
TCU-EP
external power supply


Option TCU DR
second display, 14mm red, for TCU H1
Option TCU DG
second display, 14 mm green, for TCU H1
Option TCU DY
second display, 14 mm yellow, for TCU H1


front

front

front


The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.
Erde
Abstand Englisch home ueber uns Inhalt
Produkte Service Projekte FAQ
sales Email Imprint
© Alpermann+Velte 1996 - 2011; March 04, 2011